A span too long or too heavy for one lift goes up in pieces. Each piece lands on a temporary bent, the splices are made, and the bents are jacked down and taken away. This tool designs one bent: the load from the girders, a braced tower of steel pipe legs, header and saddle beams, the jacks, holding-down bolts where a corner lifts, the concrete pad under it and the cost. A concept sketch, not for construction.
Designing…
Bents fail at the bottom and at the top. At the bottom, a pad on fill settles under a load that stays for weeks, so the girder level is checked and shimmed. At the top, a piece that is landed but not yet braced can roll over in the wind: keep the crane on until the cross frames are in. Release the bents by jacking in small equal steps, never by cutting the shims.
Inputs are saved on this device · reset to defaults
The span is divided into pieces by the bents. With the splices made, each girder line is a continuous beam over the bents, and the worst bent carries the reaction of that beam under the girder weight (with an allowance for cross frames and fittings), factored 1.25 on the dead load and 1.5 on the construction load, or the dead load with 10 % impact as a piece lands, whichever is larger.
Across the bridge the tower resists the wind on the girders or 2 % of the dead load, whichever is larger; along the bridge it resists the friction of the sliding plates as the girders move with temperature. Both act high above the ground, so they add a push-pull to the legs. The legs, the bracing, the header beams and the saddle beams are checked to AISC 360-16 with the same member functions as the Trestle tool. Every tower from 1.5 to 6 m long, with two to eight legs in a row, is designed and the cheapest is kept.
The pad is sized at service loads: the pressure at the corner stays within the allowable bearing pressure of the ground you choose, the resultant stays inside the middle third on the dead load alone, and sliding and the overturning of the bare tower have a factor of 1.5. The same engine prices the temporary bents of steel girders erected in pieces in Bridge Design. Related: falsework, crane pad, wind load, spread footing.
A temporary support that holds part of a bridge span while it is being built: usually a braced steel tower on a concrete pad, placed under the field splices of steel girders or under the ends of precast girder segments. It carries the pieces until the splices are bolted or the closure pours and tendons are done, then it is jacked down and removed.
It depends on the piece a crane can lift and a trailer can carry. For steel plate girders the pieces are commonly 30 to 40 m long, so the tool starts from one bent for each 40 m of span beyond the first; spliced precast girders usually need two towers a span, under the two splices. You can set the number yourself.
More than the weight of the pieces that rest on it. Once the splices are bolted the girder is continuous over the bent, and an intermediate support of a continuous beam takes 1.10 to 1.25 times the simple share. The tool finds the reaction from a continuous beam on the bents and adds 10 % for a piece landing.
Bare steel girders are light and catch a lot of wind. The wind pushes at girder level, far above the ground, so the tower rocks: the leeward legs take more and the windward legs less. When the push-pull is more than the dead load on a corner leg, that leg is in tension and has to be bolted down to a pad heavy enough to hold it.
After the splices are fully bolted and, for steel girders, before the deck is cast, so the girders carry the wet concrete as designed. If the bents stay in for the pour, they carry the slab too and the girder ends up with a different locked-in stress: the tool can size the bent for that case, but the girder design must agree with it.